Permiserts | Print |
Permiserts represent the best technique for providing corrosion protection of both the coupling and pin end of Permilined tubing.  Permiserts consist of two inter-locking plastic pieces which are cemented in place and are sealed at make up with Permitek, a plant applied mastic.  Permiserts have been in use for over 25 years, proving their value in thousands of installations.

Permisert Advantages

  • Providing a five thread tolerance at make up
  • Eliminating any possibility of lining eccentricity that might interfere with running survey tools
  • Preventing lining damage at pin end due to over torque



Joint Protection

Excellent protection of the coupling area is provided by a permanently flexible, plant applied mastic.  Numerous additional advantages are gained by the use of inter-locking plastic insert units known as Permiserts (only on 2 3/8", 2 7/8" and 3 1/2" EUE).

Tubing weights and dimensions

Tubing Size
O.D.
Tubing Wall
Thickness
Lining Thickness
Tubing I.D. Lined
Drift I.D. Lined
2 3/8.190" 0.156"1.682"
1.562"
 2 7/8"
.217"
0.156"
2.128"
2.000"
3 1/2"
.254"
0.188"
2.617"
2.562"
4 1/2"
.271"
0.219"
3.520"
3.375"

Tubing Size
O.D.
Tubing Weight Per Foot
Lining Weight Per Foot
Lined Weight Per Foot
2 3/84.700#
.85#
5.55#
 2 7/8"
6.500#
1.05#
7.55#
3 1/2"
9.300#
1.55#
10.85#
4 1/2"
12.750#
2.41#
15.16#

**Allowed tolerance +/- 1/32".

 
 
Permiline
Fluoroline
Permiserts
Fiberline FB™
Fiberserts™
Ryt-Wrap™
Synergy®
Stainless Steel Liner
IPC 1505
IPC 101
IPC 1850

 


© 2008 Permian Enterprises, Inc.